TC 6.6kW Air-Cooled Charger - Electric GT

TC 6.6kW Air-Cooled Charger

DETAILS

Electric GT 6.6kW Air Cooled Charging Systems by TC Charger

Support & Resources Select to dowload PDF

Invalid Email
Please check the captcha to verify you are not a robot.

Quick Specs

TECHNICAL DATA
• AC Input Voltage Range: AC90V~AC265V
• AC Input Frequency: 45~65 Hz
• AC Power Factor: ≥0.98
• Full Load Efficiency: ≥93%
• Mechanical Shock & Conformance to
• Vibration Resistance Level 10-25Hz Amplitude 1.2mm, 25-500Hz 30m/s2, 8hrs per direction
• Environmental Enclosure: IP67
• Operating Temperature: -35℃~+85℃
• Storage Temperature:-55℃~+100℃
• Mechanical Dimensions: (mm) 239(L)*135(W)*125(H)
• Net Weight: 6.4kg

PROTECTION FUNCTION
• Input Over-voltage Protection : AC270±5V
• Input Under-voltage Protection: AC85±5V
• Output Over-voltage Protection: Stop the output when exceeds +1% of the maximum output voltage
• Output Under-voltage Protection: Stop the output when below -5% of the minimum output voltage
• Output Over-current Protection: Stop the output when exceeds +1% of the maximum output current
• Over-temperature Protection: Power down from 85℃ and turn off at 90℃
• Short-circuit Protection: Stop Output
• Battery Reverse Connect Protection: Fuse Burn-out
• Ground Protection: ≤100mΩ
• CAN communication Protection: Automatically stop the output when CAN communication fails
• Power-off Protection: Yes

LED STATUS INDICATOR
1)Initial State Red Off Green Off Red Off Green Off Red Off Green Off Red Off Green Off
2)Charge State Red Off Red Off Red Off Red Off Red Off Red Off Red Off Red Off
3)Stand-by State Green Off Green Off Green Off Green Off Green Off Green Off Green Off Green Off
4)Fault Checking Red Green………………….…………Wrong Battery
Green Red…………………….………Wrong Input Voltage
Green Red Green……………..……Internal Temperature Protection
Green Red Green Red……………Wrong Hardware
Red Green Red…………………..…Wrong Communication
Red Green Red Green……………Other error status word error